27
COMPACT
®
NS circuit breaker
Rotary operating handles
Operation
The direct rotary handle maintains:
Suitability for isolation;
Indication of three positions O (off), I (on) and tripped;
Access to the "push-to-trip" button;
Visibility of and access to trip unit settings;
COMPACT
®
NS250N circuit breaker
with direct rotary handle.
COMPACT
®
NSF250N circuit breaker with extended rotary
handle.
Door mounted
Makes it possible to operate circuit breakers installed inside an enclosure from the front.
The handle mechanism can be used in NEMA 3R and 12 enclosure applications.
Degree of protection: IP40 as per IEC 529.
Operation
The unit maintains:
Suitability for isolation;
Indication of the three positions O (off), I (on) and tripped;
Visibility of and access to trip unit settings when the door is open;
Door opening prevented when circuit breaker is on;
The circuit breaker may be locked in the off position by using one to three
padlocks, padlock shackle diameter 0.19 to 0.31 inch (5 to 8 mm) (padlocks are not
supplied). Locking prevents opening of the switchboard door.
Models
Standard with black handle;
VDE type with red handle and yellow bezel for machine tool control.
Installation
The extended rotary operating handle is made up of:
A unit that replaces the front accessory cover of the circuit breaker (secured by
screws);
An assembly (handle and front plate) on the door that is always secured in the
same position, whether the circuit breaker is installed vertically or horizontally;
An extension shaft that must be adjusted. The distances between back of circuit
breaker and door are:
COMPACT
®
NSF150/250 circuit breakers: 7.4 to 24 inches (185 to 600 mm),
COMPACT
®
NSJ400/600 circuit breakers: 8.4 to 25 inches (210 to 625 mm).
Variation for COMPACT
®
NSF150 to NSJ600 circuit breakers
For withdrawable configurations, the extended rotary handle is also available with a
telescopic shaft with two stable positions.
The extended rotary operating handle is Listed under UL file E103955 and Certified
under CSA file LR 69561.
86037
86039
E36970
Directly mounted
Installation
Replaces the circuit breaker front accessory cover (secured by screws).
Models
Standard with black handle;
VDE type with red handle and yellow bezel for machine tool control.
Variations for COMPACT
®
NSF150 to NSJ600 circuit breakers
Accessories transform the standard direct rotary handle for the following situations:
Motor control centers (MCCs):
Door opening prevented when circuit breaker is on;
Circuit breaker closing inhibited when door is open;
Machine tool control, complies with CNOMO E03.81.501N, degree of protection IP54.
The directly-mounted rotary operating handle is Listed under UL file E103955 and
Certified under CSA file LR 69561.
The circuit breaker may be locked in the off position by using one to three
padlocks, padlock shackle diameter 0.19 to 0.31 inch (5 to 8 mm) (padlocks are not
supplied).
COMPACT
®
NS circuit breaker: functions and characteristics
Accessories
tripped
reset
ON
I
OFF
O
Tripped
I/ON
(Closed)
O/OFF
(Open
isolated)
Closing
Reset
Vue de la page 28